The Kohler 60RCLB produces 60kW on propane and 58kW on natural gas. It uses a KG6208, 6.2L V8 engine running at 1,800 rpm, with 144kVA of peak motor-starting capability.
The Kohler 60RCLB is intended for homes or properties whose measured loads justify 58kW on natural gas or 60kW on propane, and the associated infrastructure.
Kohler 60RCLB questions answered: sizing, cost, fuel and maintenance
Ready for a quote? Find a Kohler-certified dealer near you for installation, warranty registration and service.
Kohler 60RCLB Specifications
| Specification | Kohler 60RCLB |
|---|---|
| LP / natural-gas output | 60 / 58 kW |
| Motor-starting rating | 144 kVA peak; not continuous kW |
| Engine | KG6208, 6.2L V8 |
| Cooling / engine speed | Liquid-cooled / 1,800 rpm |
| Starting MSRP | $28,304; equipment only |
| Weight | 1,894 lb |
| Starting battery | Group 24, 12V, minimum 630 CCA |
| NG at half / full load | 493 / 1013 ft³/hr |
| LP vapor at half / full load | 191 / 357 ft³/hr |
| Catalog sound: exercise / operation | 57 / 61 dBA; see measurement caveat |
| Controller | RDC2 |
| Application | Utility backup |
Scope: U.S. 120/240V single-phase, 60Hz configuration. MSRP and catalog sound figures checked September 30, 2026. Fuel figures follow the linked April 2026 technical sheet.
Source: Kohler 60RCLB technical specification.
Source: Kohler 60RCLB consumer catalog.
Where the 60RCLB Fits
The Kohler 60RCLB is intended for homes or properties whose measured loads justify 58kW on natural gas or 60kW on propane, and the associated infrastructure. On natural gas, plan against 58kW rather than the propane nameplate. The 144kVA starting rating describes a short motor-start event and cannot be added to the running output.
Inventory the loads you need during an outage, including HVAC starting current, pumps and electric heat. Use the generator size calculator to organize the load list, then have an installer check the design against the exact alternator and fuel configuration.
Equipment Cost and Installation Scope
Kohler’s starting equipment MSRP for the 60RCLB is $28,304, checked September 30, 2026. That is not an installed price.
A complete quote should itemize the generator, compatible transfer switch, battery, foundation, electrical and fuel work, permits, commissioning, registration and any load controls or cold-weather accessories. Long trenching runs, gas-meter upgrades and changes to service panels can materially change the total. Compare equivalent scopes from local installers; no national installed average is asserted here.
Source: Kohler 60RCLB consumer catalog.
Transfer Switch and Fuel Supply
Budget and specify the automatic transfer switch separately unless the seller explicitly includes a compatible unit in the quoted package. Match switch amperage, service-entrance suitability, number of panels and load management to the installation design. A generator’s kW rating alone does not determine the correct transfer switch.
Source: Kohler 60RCLB technical specification.
At full load, the technical sheet lists 1013 ft³/hr of natural gas and 357 ft³/hr of LP vapor. Have the installer check fuel supply with the other connected appliances operating; a meter label or short pipe run alone does not establish sufficient capacity.
Ownership and Service
TP-7102 lists oil and filter changes yearly or at 150 operating hours. Check oil every 24 hours or before each day’s operation. Use the complete current manual for air-filter, ignition, battery and other service tasks. Severe conditions may require shorter intervals; match the manual to your model and serial number.
Source: Kohler 60RCLB operation manual.
Compare the Kohler Line
Compare running output on your actual fuel, peak motor starting, cooling architecture and installed system cost. Local commissioning, parts access and service response are material parts of the purchase.