The Generac 28 kW home standby generator sits at the top of Generac's current air-cooled residential range.
It is designed for homeowners who need more capacity than the 22 kW or 26 kW models without moving into a larger liquid-cooled standby system.
The current Generac 28 kW model is rated at:
- 28 kW on liquid propane
- 25 kW on natural gas
- 524 lb
- 46.4 in long × 26.3 in wide × 30.7 in high
- 125-amp main line circuit breaker
- G-Force 1000 engine
- Natural gas or liquid propane operation
Because Generac has sold different standby-generator generations over time, always check the exact model number before using specifications for installation, service or replacement parts.
Compare Generac standby generators →
Generac 28kW Specifications
| Specification | Current Generac 28kW |
|---|---|
| Rated output - LP | 28 kW |
| Rated output - natural gas | 25 kW |
| Fuel | Natural gas or liquid propane |
| Weight | 524 lb |
| Length | 46.4 in |
| Width | 26.3 in |
| Height | 30.7 in |
| Engine | Generac G-Force 1000 |
| Engine displacement | 997 cc |
| Main breaker | 125 amp |
| Enclosure | Aluminum |
| Oil capacity | 2.2 qt |
| Controller | Power Zone 200 |
| Mobile monitoring | Available |
| Quiet Test | Available |
Specifications can change by SKU and model generation. Use the exact Generac model number when confirming installation or service details.
How Much Does a Generac 28kW Generator Weigh?
The current Generac 28 kW home standby generator weighs approximately 524 pounds.
Its listed dimensions are approximately:
46.4 inches long × 26.3 inches wide × 30.7 inches high.
That is the generator itself, not necessarily the packaged shipping weight.
For transport, lifting or placement planning, use the shipping information for the exact SKU being supplied.
Generac 28kW Dimensions
The current 28 kW enclosure measures approximately:
46.4 × 26.3 × 30.7 inches
That is roughly:
- 3.87 ft long
- 2.19 ft wide
- 2.56 ft high
These dimensions are the enclosure size, not the complete installation footprint.
The installer still needs to account for:
- Required clearances
- Airflow
- Service access
- Doors and windows
- Fuel connection
- Electrical connection
- Local code
How Much Power Does a Generac 28kW Produce on Natural Gas?
The current Generac 28 kW model is rated at:
25 kW on natural gas
and
28 kW on liquid propane.
That difference matters.
The model name does not mean the unit produces 28 kW on both fuels.
If your home requires more than 25 kW of continuous output while running on natural gas, the 28 kW model may still be too small.
Always size from the fuel-specific rating.
How Many Amps Is a Generac 28kW Generator?
At 240 volts, 28 kW corresponds to approximately:
116.7 amps
The current model uses a 125-amp main line circuit breaker.
Do not use a simple watts-to-amps calculation to design the transfer equipment or wiring.
The complete electrical system should be sized from the manufacturer's specifications and local code.
Is 28kW Enough to Power a Whole House?
For many large homes, yes.
A 28 kW Generac can provide broad or whole-home backup where the home's simultaneous electrical demand fits inside the generator's fuel-specific capacity.
It is especially relevant where the property has:
- Multiple central air conditioners
- Heat pumps
- Well pumps
- Pool or spa equipment
- Electric water heating
- Electric cooking
- Larger motor loads
But 28 kW is not automatically enough for every large home.
A heavily electrified property can still exceed this capacity.
What Size House Can a Generac 28kW Run?
There is no reliable square-footage rule for a 28 kW generator.
Electrical demand matters more than floor area.
A 4,500-square-foot home with gas heat and gas water heating may require less generator capacity than a smaller all-electric house.
Proper sizing should consider:
- Running load
- Motor starting load
- HVAC
- Electric heating
- Water heating
- Pumps
- Cooking equipment
- Pool equipment
- Other major loads
- Load management
Square footage is useful for rough context only.
Who Is the Generac 28kW Best For?
The 28 kW class is most relevant for homeowners who:
- Need the maximum capacity available in Generac's current air-cooled range
- Are already close to the limit of a 26 kW system
- Have several large simultaneous loads
- Want broad whole-home backup
- Prefer not to move to a larger liquid-cooled platform
It is less compelling if a 22 kW or 26 kW system already covers the house comfortably.
Generac 28kW Fuel Consumption
Fuel consumption changes with electrical load.
The current Generac specifications list approximately:
Natural Gas
- 182 ft³/hr at 50% load
- 297 ft³/hr at 100% load
Liquid Propane
- 2.23 gal/hr at 50% load
- 3.97 gal/hr at 100% load
Actual use can vary with:
- Electrical load
- Fuel pressure
- Ambient conditions
- Generator condition
- Installation
How Much Natural Gas Does a Generac 28kW Use?
At full published load, the current 28 kW model uses approximately:
297 cubic feet of natural gas per hour.
At 50% load:
182 cubic feet per hour.
The gas system must be sized for the generator while also accounting for other gas appliances that may operate during an outage.
That can make gas-meter and pipe capacity an important part of the installation.
How Much Propane Does a Generac 28kW Use?
The current specification lists approximately:
- 2.23 gallons per hour at 50% load
- 3.97 gallons per hour at full load
Runtime depends on:
- Usable propane capacity
- Average electrical load
- Other propane appliances
- Desired reserve
Do not estimate runtime from nominal tank capacity alone.
How Long Will a Generac 28kW Run on a 500-Gallon Propane Tank?
A nominal 500-gallon propane tank is not normally filled with 500 usable gallons.
Actual runtime depends heavily on generator load.
At approximately half load, the current 28 kW uses far less propane than it does at full load.
For realistic outage planning, calculate runtime from:
- Actual usable fuel.
- Expected average generator load.
- Other propane consumption.
- A reasonable reserve.
What Engine Is in a Generac 28kW?
The current Generac 28 kW uses the Generac G-Force 1000 engine.
The engine has a displacement of approximately 997 cc.
The exact service parts depend on model generation, so use the model number before buying:
- Oil filter
- Air filter
- Spark plugs
- Battery
- Other maintenance parts
What Battery Does a Generac 28kW Use?
The current next-generation 28 kW platform specifies an AGM powersport battery that meets Generac's published requirements.
Do not buy a replacement battery based only on the generator's kW rating.
Confirm the exact model and manual first.
How Loud Is a Generac 28kW?
Generac's current air-cooled 22-28 kW platform uses a sound-attenuated enclosure and reduced-speed exercise technology.
Perceived sound depends on:
- Load
- Distance
- Installation location
- Walls
- Fences
- Hard reflective surfaces
- Landscaping
Compare noise figures only when they are measured using the same test conditions.
How Much Does a Generac 28kW Cost?
Generac currently lists the base 28 kW cellular model at approximately:
$8,159 starting MSRP
before installation.
A bundled 28 kW package with transfer equipment costs more.
The complete installed price can also include:
- Automatic transfer switch
- Electrical work
- Natural-gas or propane work
- Generator pad
- Load management
- Permits
- Trenching
- Commissioning
The generator price is not the finished project price.
Generac 28kW Installed Cost
The total installed cost varies by property.
Major cost factors include:
- Generator location
- Distance to electrical service
- Distance to fuel supply
- Gas-meter capacity
- Propane infrastructure
- Transfer equipment
- Trenching
- Permits
- Load management
A larger generator can also expose weaknesses in existing fuel infrastructure that a smaller generator would not.
Does the Generac 28kW Include a Transfer Switch?
It depends on the SKU.
Generac currently sells both:
- A standalone 28 kW generator
- A 28 kW package with transfer equipment and additional bundled components
Do not compare prices until you know whether both offers contain equivalent hardware.
Check:
- Generator model
- Transfer-switch model
- Transfer-switch amperage
- Service-entrance configuration
- Included accessories
Generac 28kW Installation Requirements
A typical 28 kW installation can require:
- Approved foundation
- Correct generator clearances
- Adequate fuel supply
- Transfer switch
- Electrical connection
- Permits
- Inspection
- Startup and commissioning
The exact requirements depend on the model and local jurisdiction.
Does a Generac 28kW Need a Concrete Pad?
Not necessarily.
Depending on the approved installation method, the generator may use:
- Composite pad
- Concrete
- Properly prepared aggregate base
The foundation needs to remain stable, level and suitable for drainage and service access.
Generac 28kW Natural Gas vs Propane
The current model supports both fuels.
Natural Gas
Maximum published output:
25 kW
Potential advantages include:
- Utility-fed supply
- No on-site fuel storage
- Convenient extended operation where natural gas remains available
Potential installation issues include:
- Gas-meter capacity
- Pipe sizing
- Pressure
- Utility upgrades
Propane
Maximum published output:
28 kW
Potential advantages include:
- Full 28 kW rated capacity
- Stored fuel on the property
- Availability where natural gas is not present
Potential issues include:
- Tank capacity
- Refill logistics
- Runtime
- Regulator and piping requirements
Generac 28kW vs 26kW
The current 28 kW provides only a modest capacity increase over the 26 kW:
On Propane
- 26 kW model: 26 kW
- 28 kW model: 28 kW
Difference:
2 kW
On Natural Gas
- 26 kW model: 24 kW
- 28 kW model: 25 kW
Difference:
1 kW
That makes the 26 vs 28 decision very different from 22 vs 26.
The 28 kW makes sense when that final 1-2 kW genuinely solves the load problem.
If the 26 kW already has comfortable headroom, the 28 kW may offer little practical benefit.
Generac 28kW vs 22kW
Compared with the current 22 kW:
Liquid Propane
- 22 kW: 22 kW
- 28 kW: 28 kW
Difference:
6 kW
Natural Gas
- 22 kW: 21 kW
- 28 kW: 25 kW
Difference:
4 kW
That additional capacity is much more meaningful for houses with several large simultaneous loads.
But the 28 kW should still be justified by a load calculation rather than bought simply because it is the largest air-cooled option.
Can a Generac 28kW Run Two AC Units?
Often, yes.
But exact suitability depends on:
- AC tonnage
- Compressor starting requirements
- Other simultaneous loads
- Soft-start equipment
- Load management
The 28 kW gives more headroom than the 22 kW or 26 kW models, but it does not make load calculation irrelevant.
Can a Generac 28kW Run Three AC Units?
Potentially.
Three smaller or well-managed systems can be easier to support than two very large compressors plus several heavy appliances.
The installer should calculate:
- Running current
- Starting current
- Other loads
- Simultaneous demand
- Load-shedding strategy
Do not size from the number of AC condensers alone.
Load Management With a Generac 28kW
Even at the top of the air-cooled range, load management can still be useful.
A home may contain:
- Multiple HVAC systems
- Electric water heating
- Pool equipment
- Dryer
- Electric cooking
Not all of those loads need to operate simultaneously.
Load management can:
- Prevent overload
- Prioritise critical loads
- Reduce peak generator demand
- Improve system flexibility
Buying the largest air-cooled generator does not mean every circuit should be allowed to start at once.
Is the Generac 28kW Worth It?
The 28 kW is worth considering when:
- 26 kW is genuinely marginal
- The additional 1-2 kW solves a real load problem
- You want to remain on an air-cooled platform
- The installed price difference is acceptable
- The fuel system can support the generator
It is less attractive when:
- 26 kW already has comfortable headroom
- The larger model forces an expensive fuel-system upgrade
- The extra capacity would rarely be used
When I Would Choose the 26kW Instead
I'd stay with the 26 kW when:
- It comfortably covers the calculated load
- Load management handles occasional peaks
- The 28 kW adds no useful capability
- The installed-price gap is meaningful
- Fuel infrastructure is already well matched to the 26 kW
The 28 kW should earn the upgrade.
When I Would Choose the 28kW
I'd choose the 28 kW when:
- The 26 kW sits too close to maximum load
- Natural-gas demand falls between 24 and 25 kW
- Propane demand falls between 26 and 28 kW
- The additional capacity prevents moving into a more expensive system class
- The fuel and electrical infrastructure can support it
When You Need More Than 28kW
The 28 kW is the top of Generac's current air-cooled residential range.
If the calculated load still exceeds its usable capacity, the answer is not to force the 28 kW harder.
Consider:
- More aggressive load management
- Reducing the backed-up load
- Larger liquid-cooled standby systems
This is where system design matters more than simply choosing the biggest air-cooled generator available.
Generac 28kW Maintenance
Routine maintenance can include:
- Engine oil
- Oil filter
- Air filter
- Spark plugs
- Battery
- Inspection
- Exercise-cycle checks
For extended outages, maintenance intervals become especially important because standby generators may accumulate many operating hours quickly.
Follow the manual for the exact model and operating conditions.
Generac 28kW FAQs
How much does a Generac 28kW generator weigh?
The current Generac 28 kW home standby generator weighs approximately 524 lb.
What are the dimensions of a Generac 28kW generator?
The current model measures approximately 46.4 × 26.3 × 30.7 inches.
How much power does a Generac 28kW produce on natural gas?
The current model is rated at 25 kW on natural gas.
How much power does a Generac 28kW produce on propane?
The current model is rated at 28 kW on liquid propane.
How much natural gas does a Generac 28kW use?
Generac lists approximately 182 ft³/hr at 50% load and 297 ft³/hr at full load.
How much propane does a Generac 28kW use?
Generac lists approximately 2.23 gal/hr at 50% load and 3.97 gal/hr at full load.
Can a Generac 28kW power a whole house?
It can provide broad or whole-home backup for many large homes, but exact suitability depends on electrical load and fuel choice.
Is 28kW better than 26kW?
Only when the additional 1-2 kW of usable capacity solves a real load problem. Otherwise, the 26 kW can be the better-value system.
Is the Generac 28kW bigger than the 26kW?
The current 26 kW and 28 kW models share the same published enclosure dimensions and both weigh approximately 524 lb.
Does a Generac 28kW include a transfer switch?
Some packages include transfer equipment and some do not. Check the exact SKU before comparing prices.
How much does a Generac 28kW cost?
Generac currently lists the base 28 kW cellular model at approximately $8,159 starting MSRP, before installation.
Is the Generac 28kW the largest air-cooled Generac?
Yes. The current 28 kW model sits at the top of Generac's next-generation 10-28 kW air-cooled home standby range.
Bottom Line
The Generac 28 kW is the maximum-capacity option in Generac's current air-cooled residential lineup.
Its current specifications include:
- 28 kW on propane
- 25 kW on natural gas
- 524 lb
- 46.4 × 26.3 × 30.7 in
- 125A breaker
- G-Force 1000 engine
The key comparison is not whether 28 kW is “better” than 26 kW.
It is whether the extra:
- 2 kW on propane
- 1 kW on natural gas
actually solves a load problem.
If yes, the 28 kW makes sense.
If not, save the money and install the correctly sized system.
Calculate your generator size →